HomeTransformerXfmr SearchContact Us

Featured Transformers

Picture Avail Transformer ID MVA High Voltage Low Voltage Impedance Phase Manufacture LTC Note
No Pictures 3321   34500 12470y/7200   3 Unknown WO/LTC  
Pictures 3705   12470x24940 480y/277   3 Cooper W/LTC  
  1330 .167 2400/4160y 480   1 Unknown WO/LTC  
  2255 .333 13800 2400/4160Y/2400   3 Westinghouse WO/LTC  
No Pictures 2450 .5 4160 480y/277 3.93 3 Unknown WO/LTC  
Pictures 3954 .5/.56 2400 480y   3 RTE WO/LTC  
  1344 .75 13200 480   3 Westinghouse WO/LTC  
  2205 .75 13000grdy/7500 216y/125   3 Unknown WO/LTC  
  1328 .833 34500 7200/12470y   1 Unknown WO/LTC  
  1327 .833 69000 7200/12470y   1 Unknown WO/LTC  
No Pictures 2465 1 12470 4160y/2400   3 Unknown WO/LTC  
Pictures 1502 1 34500 7200/12470yX2400/4160y   1 AC WO/LTC  
  990 1.25 44000 7200/12470y 6.3 1 WEST wo/LTC  
  1321 1.25 34500 7620/13200y   1 GE WO/LTC  
  1361 1.5 44000 13800   3 Unknown WO/LTC  
  1323 1.5 12470y/7200 480   3 Unknown WO/LTC  
Pictures 2976 1.5 13200y/7620 480y/277 5.3 3 RTE WO/LTC  
No Pictures 2966 1.5 125 60   3 ABB WO/LTC  
  2203 1.5 12470grdy/7200 480y/277   3 Unknown WO/LTC  
  1394 1.5 7200 480 6.00 3 GE WO/LTC  
Pictures 2087 1.5 67000 13200Y/7620 7.5 3 GE W/LTC  
Pictures 2086 1.5 67000 13200Y/7620 7.14 3 GE W/LTC  
No Pictures 3011 1.5 22900 4160y/2400   3 Unknown WO/LTC  
No Pictures 3587 1.5 12000 2400X7200   3 GE WO/LTC  
Pictures 3903 1.5/1.68/1.725/1.932 12470 480y/277   3 Westinghouse WO/LTC  
  1286 1.5/1.680 33000 4160y/2400   3 Westinghouse WO/LTC  
  1393 1.667 66000 2400   1 Westinghouse WO/LTC  
Pictures 2267 1.667 69000x34500 7200/12470y 7.9 1 Westinghouse WO/LTC  
Pictures 3706 1.667 66000 6600/12000y 7.0% 1 Westinghouse WO/LTC  
No Pictures 2664 1.667 43800 12470y/7200   1 Westinghouse WO/LTC  
No Pictures 3296 1.8 4160y 620   3 Niagra WO/LTC  
  1386 10 67000X33500 13090y/7560   3 Westinghouse W/LTC  
No Pictures 2323 10 115000y 46000y   3 UST WO/LTC  
Pictures 4032 10 13800 4160y/2400   3 AEG WO/LTC  
No Pictures 2458 10 13200 4160y/2400   3 Unknown WO/LTC  
No Pictures 3191 10 138000 12470y/7200   3 GE W/LTC  
  1496 10 67000 12470y/7200   3 ABB WO/LTC  
No Pictures 3610 10 69000 12470y/7200   3 Unknown W/LTC  
No Pictures 2967 10 23000 12470y/7200   3 Unknown WO/LTC  
No Pictures 3831 10.14 43800 13800y/7970   3 Westinghouse Unknown  
No Pictures 3322 10.5 34500 12470y/7200   3 Unknown WO/LTC  
No Pictures 3318 10.5 34500 12470y/7200x8320y/4800x480   3 Unknown Unknown  
No Pictures 3317 10.5 34500 12470y/7200   3 Unknown Unknown  
No Pictures 3550 10/11.2/12.5/14 43800 12470y/7200 6.5 3 UST W/LTC  
  1359 10/11.2/12.5/14 43800grdy/25299 13200   3 GE WO/LTC  
No Pictures 2880 10/11.2/14 67000 13200y/7620   3 GE W/LTC  
Pictures 4000 10/12.5 67000 12470y 7.6 3 Westinghouse W/LTC  
Pictures 2224 10/12.5 16340Y/9430 4160   3 Uptegraf WO/LTC  
Pictures 4026 10/12.5 ffa 34400 13090y/7560   3 Waukesha WO/LTC  
No Pictures 3829 10/12.5/14 138000 34500y   3 Unknown Unknown  
No Pictures 3541 10/12.5/14 115000 x 67000 13200y/7620 8 3 DeltaStar WO/LTC  
  1305 10/12.5/14 34400 12470y/7200 6.5 3 Westinghouse W/LTC  
No Pictures 3937 10/12.5/14 46000 12470y/7200   3 UST W/LTC  
No Pictures 3863 10/12.5/14 67000 12470y/7200   3 Westinghouse Unknown  
Pictures 3897 10/12.5/14 13800 15120 8.71% 3 GE WO/LTC  
No Pictures 3906 10/12.5/14 43800 12470y/7200   3 Westinghouse W/LTC  
No Pictures 4014 10/13.33 13800 4160y/2400   3 GE WO/LTC  
Pictures 4031 10/13/16.6 115000y/66395 24940y/14400   3 Virginia WO/LTC  
No Pictures 3845 10/14 43800 12470Y/7200   3 GE WO/LTC  
  1281 10/14 132000 26400y/15242 8 3 HeviDuty WO/LTC  
No Pictures 3835 10/14 134000 13090y   3 Khulman WO/LTC  
Pictures 4024 10/14 161000 12470y/7200   3 Khulman W/LTC  
No Pictures 2748 10/14 138000 12470y/7200   3 Waukesha WO/LTC  
No Pictures 3909 10/14 67000 24900y/14400   3 GE WO/LTC  
  1284 10/14/16 46200y/26674 13200   3 GE WO/LTC  
  1377 12 69000 12470Y/7200   3 Unknown W/LTC  
No Pictures 3823 12.5 22900 300 5 3 GE Unknown  
Pictures 3896 12.5/14 144900 26180 GrdY/ 15115 10.4 3 FedPacific W/LTC  
No Pictures 3923 12/13.4 67000y 13800y/7970   3 Khulman W/LTC  
No Pictures 3590 12/13.45/15/17.9/20/22.4 34400 13090Y/7620 5.1 3 Westinghouse W/LTC  
No Pictures 3922 12/16 67000y 13800y/7970   3 Cooper W/LTC  
  1388 12/16 115000GRDY/66395 13800 8.0 3 GE WO/LTC  
Pictures 4030 12/16 12000 4160y/2400   3 Moloney WO/LTC  
Pictures 3132 12/16.8 26400 4160 6.2 3 Unknown Unknown  
No Pictures 3858 12/16/18 18000 4160   3 Unknown WO/LTC  
No Pictures 4043 12/16/20 110000grdy/63510 4160   3 Waukesha WO/LTC  
No Pictures 3836 12/16/20 67000 26400yx13200y   3 Westinghouse W/LTC  
No Pictures 3969 12/16/20 67000,69000 12470y/7200   3 Unknown Unknown  
No Pictures 4017 12/16/20 115000y 4160   3 Waukesha W/LTC  
No Pictures 2962 12/16/20 67,000 12470Y/7200 6.5 3 McGrawEdison WO/LTC  
No Pictures 3979 12/16/20 161000 4160y/2400   3 DeltaStar WO/LTC  
No Pictures 2648 12/16/20 69000 4160y/2400 6.7 3 Westinghouse WO/LTC  
No Pictures 3319 12/16/20 115000 24940y/14400   3 AC WO/LTC  
Pictures 2670 12/16/20 68800 13090y/7560   3 HeviDuty WO/LTC  
No Pictures 3928 12/16/20 34500 4160y/2400   3 ABB WO/LTC  
Pictures 4027 12/16/20/22.4 66000 13800y/7970   3 GE WO/LTC  
Pictures 3555 12/16/20/22.4 67000 4160y/2400 7.8 3 Westinghouse W/LTC  
Pictures 3933 12/16/20/22.4 138000x69000 26.18yx13.09y 9.72 3 Waukesha W/LTC  
No Pictures 3173 12/16/20/22.4 117000 13200y/7620   3 Waukesha W/LTC  
Pictures 3767 12/16/20/22.4 132000 13200y/7620 10.5 3 ASEA W/LTC  
Pictures 3931 12/16/20/22.4 115000y 67000y 3.73 3 Waukesha WO/LTC  
No Pictures 3865 12/16/20/22.4 69000x46000 12470y/7200 7.3 3 UST WO/LTC  
No Pictures 3289 12/16/20/22.4 138000 12470y   3 ASEA Unknown  
Pictures 3932 12/16/20/22.4 new 115000grdy 67000grdy 3.73 3 Waukesha WO/LTC  
No Pictures 4015 12/16/20? 115000 4160y/2400   3 ABB WO/LTC  
Pictures 3934 12/16/22.4 138000 26180grdy   3 Waukesha W/LTC  
No Pictures 3290 12/17.92 69000 13800y   3 Westinghouse Unknown  
No Pictures 3521 13.2/17.6/22 66000 34500Grdy/19919 7.98 3 Virginia WO/LTC  
Pictures 3968 13.4/15 Mobile 60000 Mobile 12470y/7200x4160y/2400 9.991 3 Standard W/LTC  
Pictures 3556 13.4/17.8/22.4 67000 12470y/7200 7.5 3 HeviDuty WO/LTC  
No Pictures 2964 13.5 138000 12470Y/7200   3 McGrawEdison W/LTC  
Pictures 3917 13/17.33/24.270 69000y 24900 6.96 3 Unknown WO/LTC  
No Pictures 2965 15 69000grdy/39840 14400   3 Waukesha WO/LTC  
No Pictures 3898 15/? 138000 24940y   3 OhioTransformer WO/LTC  
  1292 15/16.8 138000 6900y/3985   3 McGrawEdison W/LTC  
Pictures 2070 15/20 138000 44000 6.25 3 Khulman WO/LTC  
No Pictures 2502 15/20/16.8/22.4 138000 4160y/2400 7.8 3 DeltaStar W/LTC  
No Pictures 3966 15/20/22.4 142300` 13200y   3 McGrawEdison WO/LTC  
  2071 15/20/22.4 43800 13800y/7970   3 Khulman WO/LTC  
No Pictures 3002 15/20/22.4/28 115000 4160y/2400 7.48 3 GE WO/LTC  
Pictures 2247 15/20/25 110000 13090y/7558   3 AC W/LTC  
No Pictures 3292 15/20/25 135420y 4160y x 13200y   3 Westinghouse Unknown  
Pictures 2676 15/20/25 115000 13200y/7620   3 GE W/LTC  
  1374 15/20/25 115000grdy/66397 13800   3 Elin WO/LTC  
No Pictures 3297 15/20/25 38000y 13800   3 GE WO/LTC  
Pictures 3089 15/20/25 69000y/39839 4160 7.0 3 Westinghouse WO/LTC  
Pictures 4040 15/20/25/28 115000 24940yx12470y   3 Westinghouse W/LTC  
No Pictures 3557 15/20/25/28 67000 4160y/2400   3 Cooper WO/LTC  
No Pictures 3857 15/20/25/28 138000 13200y/7620   3 GE W/LTC  
No Pictures 4003 15/20/25/28 138000 13800y/7970   3 Unknown Unknown  
No Pictures 4039 15/20/25/28 68800 12470y/7200   3 McGrawEdison Unknown  
No Pictures 2452 15/25/28 67000 12470y/7200 7.5 3 Unknown W/LTC  
Pictures 3714 15/28 115000y 69000y 5.56 3 Virginia W/LTC  
  1293 16 138000 34500y/19900   3 Pennsylvania W/LTC  
No Pictures 3852 18 13200 330   3 Unknown Unknown  
Pictures 2221 18/24/30 230000 13800Y/7970 11.45 3 AC WO/LTC  
No Pictures 4013 18/24/30 138000 12470y/7200   3 GE W/LTC  
Pictures 4029 18/24/30 115000 34500y/19900   3 GE WO/LTC  
No Pictures 3855 18/24/30/33.4 161000 13800y   3 GE WO/LTC  
  2207 195 161000 20900   3 Westinghouse WO/LTC  
  2257 2 24900y/14400 480   3 GE WO/LTC  
Pictures 3305 2 12470 480y/277   3 GE WO/LTC  
No Pictures 2968 2 4160y/2400 480   3 Unknown WO/LTC  
No Pictures 3908 2 12470y/7200 480y/277   3 UST WO/LTC  
  2089 2.0 12470 480   3 Unknown WO/LTC  
No Pictures 3826 2.5 2300 2500 amps   1 Unknown Unknown  
Pictures 2668 2.5 34500 4160y/2400   3 Unknown WO/LTC  
  180 2.5 34400 5040 5.84% 3 ITE WO/LTC  
No Pictures 4035 2.5 138000y 69000y   3 Westinghouse WO/LTC  
No Pictures 2272 2.5 34,500 4160y/2400   3 Unknown WO/LTC  
No Pictures 2886 2.5 13200y/7620 2400/4160y   1 Unknown W/LTC  
  1322 2.5 12470y/7200 480   3 Unknown WO/LTC  
  2253 2.5 69000 2400 7.2 3 GE WO/LTC  
Pictures 2746 2.5 43800 4160y/2400   3 Unknown WO/LTC  
Pictures 2088 2.5/2.8 69000 2400 6.72 3 Westinghouse WO/LTC  
No Pictures 2970 2.5/2.8 115000 7200/12470y   1 Unknown WO/LTC  
Pictures 3904 2.5/2.815 12470 480y/277   3 Khulman WO/LTC  
  982 2.5/3.125/3.5 43800 4160Y/2400 7% 3 GE w/LTC  
No Pictures 3295 2.5/3.5 6900y 4160   3 GE WO/LTC  
No Pictures 3825 2.75 23000 1400 6.35 3 Westinghouse Unknown  
Pictures 3953 2/2.24/2.378 2400 600   3 RTE WO/LTC  
Pictures 3955 2/2.24/2.576 2400 600y/346   3 RTE WO/LTC  
No Pictures 3078 2/2.3 33000 4160y/2400   3 Unknown W/LTC  
No Pictures 3982 20/22.4/27/30/37 138000 12470y/7200   3 McGrawEdison W/LTC  
No Pictures 3846 20/25/30 69000y 34500y   3 DeltaStar WO/LTC  
No Pictures 3301 20/26.6/33.3 46000 14400y/8320   3 Westinghouse W/LTC  
No Pictures 4022 20/26.7/33.3 115000 4160y/2400   3 ABB WO/LTC  
No Pictures 3828 20/26/30 138000 34500y   3 ABB Unknown  
No Pictures 3927 20/26/33 115000 4160y/2400   3 ABB WO/LTC  
No Pictures 4042 20/27/33 115000 4160y/2400   3 ABB Unknown  
Pictures 4025 21/40 115000 13200y/7620 7.88 3 GE WO/LTC  
Pictures 2212 23.3/33.3 115000grdy/66400 13500 11.0 1 Unknown WO/LTC  
No Pictures 3194 24/32 73000y 13800   3 Unknown WO/LTC  
Pictures 3691 24/32/40 138000 34500Y/19900 8.3 3 GE WO/LTC  
  2196 240/320/400 245000 19000   3 Westinghouse W/LTC  
Pictures 4028 25 13800 395   3 Westinghouse W/LTC  
No Pictures 3300 25/28 138000 12470y/7200 8.499 3 GE WO/LTC  
Pictures 3967 25/33.3/46.6 67000 12470y/7200 7.96 3 ABB WO/LTC  
Pictures 3902 25/33/41 67000 12470y/7200   3 Westinghouse WO/LTC  
No Pictures 4012 25/33/41 287000 25000y   3 FedPioneer W/LTC  
  2197 25/33/41 110000 42000grdy/26560 8.0 3 ABB W/LTC  
Pictures 3905 25/33/41 67000 12470y/7200   3 Khulman WO/LTC  
No Pictures 3291 250 132000y 19000   3 Westinghouse WO/LTC  
No Pictures 3827 27/36/45 120000y 34500y   3 ABB W/LTC  
No Pictures 2454 275/308 525000/303109Y 24700   1 Westinghouse WO/LTC  
No Pictures 2500 28/32/47 69000y/39839 13800   3 Wagner WO/LTC  
No Pictures 2451 3 13200 480 6.16 3 ABB WO/LTC  
  2202 3 13000grdy/7500 216y/125   3 Unknown WO/LTC  
No Pictures 3824 3 22000 250 5.3 3 GE Unknown  
No Pictures 2444 3.33 2500 2500   1 Unknown WO/LTC  
No Pictures 2442 3.33 7620 7620   1 Unknown W/LTC  
  527 3.333 68800 7560/13090y 6.75 1 Unknown wo/LTC  
No Pictures 4018 3.5 4160 480y/277   3 Unknown WO/LTC  
No Pictures 4008 3.75 24940y 12470grdy/7200   3 Cooper WO/LTC  
No Pictures 2325 3.75 12470 4160y/2400 5.59 3 Unknown WO/LTC  
  1354 3.75 67000 13800 7.2 3 OhioTransformer WO/LTC  
No Pictures 3012 3.75 22900 4160y/2400   3 Unknown WO/LTC  
  1289 3.75/4.2 24000 4160y/2400   3 Westinghouse WO/LTC  
  1368 3.75/4.2/4.6/5.2 13200 4160Y/2400 5.4 3 RTE WO/LTC  
Pictures 2223 3.75/4.2/5.25 13800 2400Y/1385 5.51 3 GE WO/LTC  
No Pictures 4036 3.75/4.2/5.25 13200 8320y/4800x4160y/2400 5.8 3 HeviDuty WO/LTC  
No Pictures 3907 3.75/4.687 43800 12470yx4160y   3 T&R WO/LTC  
No Pictures 4004 3.75/5 138000 4160y/2400   3 Unknown Unknown  
  1369 3.75/5 13200 480y/277 2-2.5 3 ABB WO/LTC  
No Pictures 3294 3.75/5.25 13800 2400y   3 GE WO/LTC  
  1282 3.75/5.25 13200 4160y/2400   3 ABB WO/LTC  
  1299 3.75/5.25 69000 2400/4160y/2400   3 Westinghouse W/LTC  
  1287 3.75/5.25 26400 4160y/2400   3 AC W/LTC  
No Pictures 2655 30 100000 13200y/7620   3 Unknown WO/LTC  
No Pictures 2654 30 100000 12470Y/7200   3 Unknown WO/LTC  
Pictures 2102 30/40 64000grdy/36952 12470   3 ABB WO/LTC  
No Pictures 3832 30/40/50 115000y 13800 7.58 3 ABB WO/LTC  
No Pictures 3612 30/40/50 115000y 34500y   3 GE WO/LTC  
No Pictures 3850 30/40/50 115000y 13800   3 GE WO/LTC  
  2241 30/40/50 115000 13200y/7620   3 ABB W/LTC  
No Pictures 4016 30/40/50/56 115000 13800y-13800y   3 ABB WO/LTC  
No Pictures 3288 30/65 69000 34500y   3 FedPacific Unknown  
No Pictures 2975 300 230000y 18000   3 CaGE WO/LTC  
No Pictures 4020 318 230000y 24000   3 Westinghouse WO/LTC  
No Pictures 3299 34.8/46.4/58 115000yx69000y 34500y/19920   3 ABB WO/LTC  
No Pictures 3853 35 13800 480   3 Unknown Unknown  
No Pictures 3195 37.5/50/62.5/70 138000GRDY 13800   3 Waukesha Unknown  
No Pictures 3924 39/52/65 115000grdy 34500grdy 7.23 3 Virginia W/LTC  
No Pictures 3298 395 138000y 19000   3 OhioTransformer WO/LTC  
  2198 396.6 500000grdy/288700 22000   1 GE WO/LTC  
No Pictures 2643 4 13800 4160y/2400   3 Unknown WO/LTC  
  1389 4 34500y/19919 4160   3 Unknown WO/LTC  
Pictures 4033 40/53/66 118000grdy 13800 8.57 3 Waukesha WO/LTC  
Pictures 4041 40/53/66 118000grdy 13800 8.57 3 Waukesha WO/LTC  
No Pictures 4021 42/56 230000y 6914y-4152y-4152y   3 Westinghouse WO/LTC  
No Pictures 4019 42/56/70 24000 6900y-4160y-4160y   3 GE WO/LTC  
  399 430 345000y/199190 20900 8.99 3 WEST wo/LTC  
No Pictures 3121 45/50.4/60/67.2 140000GRDY/80830 72000GRDY/41570 5.57 3 McGrawEdison W/LTC  
No Pictures 2747 45/60/75 138000Y/79677 34500   3 Unknown W/LTC  
No Pictures 3980 45/60/75 161000y 13800y-13800y   3 ABB WO/LTC  
  2208 46 116000 42000grdy/26560   3 Westinghouse W/LTC  
Pictures 3869 46/61/76/86 120000y 13800   3 Unknown WO/LTC  
  170 5 43800 4160y/2400 7.0 3 WEST w/LTC  
  1280 5 46000 26000y/15011   3 ABB WO/LTC  
Pictures 1495 5 13800 4160y/2400   3 Unknown WO/LTC  
  1300 5 34500 4160y/2400   3 FedPioneer WO/LTC  
No Pictures 3178 5 69000 12470y/7200   3 Unknown WO/LTC  
No Pictures 3286 5 67000 24940y/14400   3 Unknown Unknown  
  1345 5 13800 4160y/2400   3 Cooper WO/LTC  
Pictures 2669 5 34500 480   3 Unknown WO/LTC  
  2199 5 11500 2400X600 4.9 3 AC WO/LTC  
  2200 5 11500 2400X600 4.9 3 GE WO/LTC  
No Pictures 2457 5 34500 2400/4160y   1 Unknown WO/LTC  
  1390 5 34500y/19919 4160   3 HKPorter WO/LTC  
No Pictures 2644 5 115000 4300y/2483   3 Unknown WO/LTC  
  1336 5 22860y/13198 6900 6.76 3 Unknown WO/LTC  
No Pictures 3711 5 67000x115000 Delta 25000y/1454 8.2% 3 DeltaStar W/LTC  
Pictures 3859 5 Mobile 110000x67000 Mobile 13200y/7620 10.77 3 Westinghouse WO/LTC  
Pictures 3974 5 Mobile 67000x46000 Mobile 24960yx12480yx4160y 10.9 3 UST WO/LTC  
  2225 5/5.6 60000 4160y/2400 7.79 3 Westinghouse WO/LTC  
  2143 5/5.6 43500 4160Y/2402 6.81 3 Unknown WO/LTC  
No Pictures 3965 5/5.6/7 13200 4360y/2500y?   3 GE W/LTC  
No Pictures 2270 5/5.6/7 115000 4160Y/2400   3 UST WO/LTC  
No Pictures 3964 5/5.6/7 13200 4360y/2500y?   3 GE W/LTC  
  987 5/5.6/7 43800 12470y/7200 7.51 3 GE w/LTC  
Pictures 2073 5/5.6/7 13800 2400Y/1385   3 GE WO/LTC  
Pictures 2269 5/5.625/6.67/7.5 110000 4160y/2400 8.83 3 Khulman WO/LTC  
  2206 5/5.68/6.25 43800X13200 13800Y/7970X4160Y/2400 10.11 3 GE W/LTC  
No Pictures 3588 5/6.25 12000 2400 5.67 3 GE WO/LTC  
No Pictures 2745 5/6.25 67000 13800y/7970 x 12470y/7200   3 Westinghouse WO/LTC  
No Pictures 4010 5/6.25 46000 12470y/7200 7.1 3 Cooper WO/LTC  
No Pictures 4009 5/6.25 67000 4160y/2400 7.8 3 Virginia WO/LTC  
Pictures 3713 5/6.25 69000 12470y/7200 8.2 3 ABB WO/LTC  
Pictures 4038 5/6.25 46000 12470y/7200 7.1 3 Cooper WO/LTC  
Pictures 4037 5/6.25 67000 4160grdy 7.8 3 Virginia WO/LTC  
Pictures 3303 5/6.25/7 67000 12470y/7200 7.5 3 HKPorter WO/LTC  
No Pictures 2646 5/6.25/7 12470y/7200 2400/4160Y/2400   3 Standard WO/LTC  
  1294 5/6.25/7 67000 13200y/7620 7.08 3 GE WO/LTC  
  903 5/6.25/7 24940y/14400 4160 5.4 3 WAG wo/LTC  
Pictures 3307 5/6.25/7 67000 12470y/7200 7.38 3 DeltaStar WO/LTC  
Pictures 3306 5/6.25/7 67000 12470y/7200 7.38 3 DeltaStar WO/LTC  
No Pictures 3854 5/6.6 67200 7.2/12.47/7.2x2.4/4.16y   3 McGrawEdison WO/LTC  
No Pictures 2652 5/7 34500 4800x8320y/4800x12470y/7200   3 Unknown W/LTC  
  1320 5/7 13800 4160y/2400 4.89 3 ABB WO/LTC  
  1290 5/7 34400 4160y/2400   3 GE W/LTC
  1356 5/7 34500Y/19900 4160   3 ABB WO/LTC  
No Pictures 3293 5/7 13800 4160y   3 Westinghouse WO/LTC  
  1555 50 21600y/12471 21600y/12471   3 Westinghouse W/LTC  
  801 50 138000grdy/79674 69000GRdY/39838 8.24 3 GE w/LTC  
No Pictures 3830 54/72/90 230000yx115000y 21600y   3 Unknown WO/LTC  
No Pictures 3544 54/72/90 138000y 34500   3 Unknown Unknown  
No Pictures 3851 6.5/20 Mobile 115000x67000 Mobile 34500yx13200y   3 DeltaStar WO/LTC  
No Pictures 3549 6/7.2/8.4 115000 13800y/7970 7.4 3 Khulman WO/LTC  
Pictures 1483 6/7.5 115000 2520/4360grdy/2520 7.2 3 RTE WO/LTC  
  1273 60/80/100 115000 69000y/39838   3 Elin W/LTC  
  1383 60/80/100 115000 69000   3 Unknown W/LTC  
No Pictures 2963 60/80/100 121OOOgrdy/69860 13800 17.232 3 GE WO/LTC  
No Pictures 3558 60/80/100/112 138000y 69000y   3 TrafoUnion W/LTC  
No Pictures 2453 7.5 12470 2400 6.16 3 ASEA WO/LTC  
No Pictures 3963 7.5 115000 12470/21600y/12470   3 Pennsylvania WO/LTC  
No Pictures 4007 7.5 24940y 12470grdy/7200   3 DeltaStar WO/LTC  
  1285 7.5 12470 2400y/1385   3 GE WO/LTC  
No Pictures 3834 7.5 44000 4160y/2400   3 Moloney WO/LTC  
No Pictures 2974 7.5 115000 13200y/7620   3 Unknown WO/LTC  
No Pictures 2884 7.5 115000 13090y x 4360y 7.5 3 Westinghouse W/LTC  
No Pictures 3589 7.5 12000 2400 5.8 3 Interstate WO/LTC  
No Pictures 3193 7.5 43800 4160y/2400 7 3 Unknown WO/LTC  
No Pictures 2321 7.5 Mobile 115000 Mobile 24000Y/13860x13800Y/7970X4160Y/2400   3 Westinghouse WO/LTC  
No Pictures 3849 7.5/10 67000 13800y   3 Waukesha WO/LTC  
  1274 7.5/10 43800 12470y/7200   3 GE WO/LTC  
No Pictures 3848 7.5/10.5 34500 4160y/2400   3 Unknown WO/LTC  
No Pictures 3916 7.5/10.5 33000 13200y   3 Niagra W/LTC  
No Pictures 3915 7.5/10.5 33000 13200y   3 ABB WO/LTC  
No Pictures 2501 7.5/10.5 Mobile 69000 Mobile 24940y/14400x12470y/7200   3 Unknown WO/LTC  
Pictures 2340 7.5/8.4 161000X118800 4160Y/2400 8.4/9.0 3 Westinghouse WO/LTC  
No Pictures 2885 7.5/8.4/10.5 115000 24900y/14400 7.89 3 ASEA WO/LTC  
No Pictures 2456 7.5/8.4/10.5 67000 12470y/7200 7.24 3 GE WO/LTC  
  897 7.5/8.4/9.3/10.5 110000 12470y/7200 8.1 3 ASEA w/LTC  
  2209 7.5/9.375 11700 2400 5.9 3 Westinghouse WO/LTC  
  2210 7.5/9.375 14400 4160Y/2400 4.5 3 Uptegraf WO/LTC  
  549 7.5/9.375 68800 13800y/7970   3 AC wo/LTC  
No Pictures 2449 7.5/9.375/10.5 67000 13090y/7560   3 GE WO/LTC  
Pictures 3304 7.5/9.375/10.5 69000 13200y/7620 7.2 3 Westinghouse WO/LTC  
No Pictures 3856 7.5/9.375/10.5 67000 13200y/7620   3 GE W/LTC  
No Pictures 2665 7.5/9.375/8.4/10.5 24940y/14399 12470y/7200   3 Khulman WO/LTC  
No Pictures 2443 7.5/9.375/8.4/10.5 43800 4160y/2400 6.9 3 AC WO/LTC  
No Pictures 3860 70 138000 13800y/7970   3 GE WO/LTC  
  2201 700 345000grdy/199200 22800 14.24 3 GE WO/LTC  
Pictures 4034 8.4/10.5 69000 x 34500 4160y/2400   3 GE W/LTC  
Pictures 3999 8/10 115000 2400/4160y/2400 9.2 3 Unknown WO/LTC  
Pictures 2222 9/12/13.4 132000 4160y/2400   3 GE WO/LTC  
Pictures 2040 9/12/13.4 132000 4160y/2400   3 GE WO/LTC  
No Pictures 3611 90 138000 13800Y/7970   3 Waukesha WO/LTC